ON-SITE MICRO-OHMMETER: OM16 + DATA MANAGEMENT SOFTWARE: Log OM
 
High accurate resistance measurement up to 10 A
Inductive and non-inductive resistances
Automatic measurement in non inductive resistance mode: one single operator needed
 
Functionalities OM 16
Measurement: Low resistance value measurement in 4-wire configuration
Inductive resistances
Non-inductive resistances
Ranges: 7 ranges from 5m to 2.5 KΩ, manual and auto ranging
High accuracy: 0.05 % RDG
Current: DC current, from 1mA to 10 A
High resolution: 0.1 µΩ
Low temperature coefficient: 10 ppm/°C
Operating modes: Manual or automatic measurement trigger:
one single operator can perform the measurement
Resistance calculation: EMF measured before each measurement
Display of temperature compensated resistance value
Choice of metal temperature coefficient
Choice of reference temperature and ambient temperature (programmed or measured with integrated sensor)
Power supply: Mains and quick charge NiMh batteries
Communication modes: RS 232
Protection: Up to 250 V
Additional functions: Two programmable thresholds
Digital calibration without internal adjustment
Storage capacity: 1000 values identified to read on display and via Log OM software or printer
Applications: Inductive resistances: coils, transformers, motor windings...
Non-inductive resistances: earth bonding, coating, contact resistances...
  Request For Quote
  PDF OM 16 data sheet
  PDF Log OM data sheet
 
OM 16
 
Hard case, plastic washable keyboard, key-locked measurement plugs
Size: 270 x250 x 180 mm
Weight: 4 Kg
Operating conditions: 0 / 50 °C, 20 / 75 % RH
 
Log OM
Full configuration of OM21 and OM 22
Download, store, read and export data from the instruments
Scaling, statistical functions, alarms...
 
 